CHVWD - BOSS 315 SILICONE SEALEANT;RTV SILICONE ADHESIVE SEALANT

  • MSDS: CHVWD
  • Manufacturer: ACCUMETRIC INC
  • Product Name: BOSS 315 SILICONE SEALEANT;RTV SILICONE ADHESIVE SEALANT
  • National Stock Number: 8040-00-851-0211
Product Identification

Product ID:BOSS 315 SILICONE SEALEANT;RTV SILICONE ADHESIVE SEALANT
MSDS Date:12/05/1997
FSC:8040
NIIN:00-851-0211
Kit Part:Y
MSDS Number: CHVWD

Responsible Party
ACCUMETRIC INC.
350 RING ROAD
ELIZABETHTOWN, KY 42701
US

Emergency Phone: 502-769-3385

Info Phone: 502-769-3385/800-928-2677

Cage: 58149

Contractor
ACCUMETRIC INC
843 ELIZABETHTOWN, KY 42701 US

Telephone: 502-769-3385

Cage: 58149

Ingredients

SILANE, METHYLTRIACETOXY-

CAS: 4253-34-3

RTECS: VV4500000

Fraction By Weight: 2.00%

OSHA PEL NOT ESTABLISHED.

ACGIH TLV: NOT ESTABLISHED.


ETHYLTRIACETOXYSILANE

CAS: 17689-77-9

Fraction By Weight: 2.00%


SILICA

CAS: 112945-52-5

RTECS: VV7310000

Fraction By Weight: 10.00%

OSHA PEL 6 MG/M3

ACGIH TLV: 10 MG/M3


POLYDIMETHYSILOXANE

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGEST:CAUSE STOMACH
DISCOMFORT.SKIN:UNCURED PROD MAY IRRIT
LIPS,GUMS,TONGUE,SKIN.EYE:UNCURED PROD IRRIT.COMMENTS:WHEN HEAT TO
TEMP >150C/300F IN PRESENCE OF IAR PROD CNA FORM FORMALDEHYDE
VAP.FORMALD EHYDE POT CANC HAZ,KNOWN SKIN/RESP SENS.VAP IRRIT
EYE/NSOE/THROAT.SAF HNDLG CONDITIONS MAY BE MAINTAINED BY
KEEPING(SUP)
Explanation of Carcinogenicity:PER MSDS:CARCINGENCITY:NTP/IARC/OSHA:NO.
Effects of Overexposure:INGEST MAY CAUSE STOMACH DISCOMFORT.SKIN
CONTACT:UNCURED PRODUCT MAY IRRIT LIPS,GUMS,TONGUE,AND SKIN.EYE
CONTACT:UNCURED PRODUCT CONTACT IRRIT EYES.
Medical Cond Aggravated by Exposure:NONE KNOWN

First Aid

First Aid:EYE:FLUSH W/WATER FOR 15MINS.OBTAIN MED ATTN.SKIN:WIPE OFF
AND FLUSH W/WATER.INHAL:REMOVE TO FRESH AIR.OBTAIN MED
ATTN.ORAL:OBTAIN MED ATTN.

Fire Fighting

Flash Point Method:OC
Flash Point:212F,100C
Lower Limits:ND
Upper Limits:ND
Extinguishing Media:WATER, WATER FOG, CO2, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIE CLOTHING SHOULD BE WORN IN FIGHTING FIRES INVOLVING
CHEMICALS.
Unusual Fire/Explosion Hazard:NONE KNOWN.

Accidental Release

Spill Release Procedures:REMOVE PRODUCT & USE ABSORBENT MATL TO TAKE
CARE OF ANY OIL-LIKE RESIDUES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE BELOW 90F.USE REASONABLE CARE
AND CAUTION.
Other Precautions:NONE KNOWN.

Exposure Controls

Respiratory Protection:ACID GAS/ORGANIC VAPOR TYPE
Ventilation:LCOA EXHAU:NONE ESTABLISHED. MECHANICAL:NONE.
SPECIAL/OTHER:NA.
Protective Gloves:USE CHEMICAL WORKERS GLOVES
Eye Protection:PROPER EYE PROT,SAF GLASSES AS MIN
Other Protective Equipment:NONE
Work Hygienic Practices:GROSS AMTS OF MATL SHOULD BE REMOED FRM SKIN AS
SOON AS PRACTICAL,ESPECIALLY BEFORE EATING/SMOKING.
Supplemental Safety and Health
HEALTH:VAP CONC W/IN OSHA PERMISSIBLE EXPO LIMIT FOR FORMALDEHYDE.

Chemical Properties

HCC:V7
Boiling Pt:B.P. Text:NA
Melt/Freeze Pt:M.P/F.P Text:NA
Decomp Temp:Decomp Text:NP
Vapor Pres:N5MM
Vapor Density:NA
Spec Gravity:1.04
pH:NP
Evaporation Rate & Reference:<1, ETHER=1
Solubility in Water:<0.1, NEGLIGIBLE
Appearance and Odor:ACETIC ACID-LIKE PASTE
Percent Volatiles by Volume:NP
Corrosion Rate:NP

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZING MATLS CAN CAUSE A REACTION.
Stability Condition to Avoid:AIR OR MOISUTRE CAUSES POLYMERIZATION AND
ACETIC ACID VAPORS ARE FORMED.
Hazardous Decomposition Products:SILICONE DIOXIDE, CARBON DIOXIDE, AND
TRACES OF INCOMPLETELY BURNED CARBON PRODUCTS.

Disposal

Waste Disposal Methods:REVIEW ALL LOCAL, STATE AND FEDERAL REGULATIONS
CONCERNING HEALTH & POLLUTION TO DETERMINE APPROVED DISOSAL METHOD.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.